Short answer
What each organisation says (pages read on 16 November 2026)
| OSHA | NIOSH | |
|---|---|---|
| Figure | Permissible exposure limit (PEL) of 90 dBA for all workers over an 8 hour day | Recommended exposure limit (REL) of 85 dBA averaged over an eight-hour workday |
| Exchange rate | 5 dBA | 3 dBA |
| Status | A standard employers must meet | A recommendation |
OSHA's page also says that general industry employers must run a hearing conservation program when workers are exposed to a time weighted average of 85 dBA or higher over an 8 hour shift. So 85 dBA appears in OSHA's rules too, as the point where a hearing conservation program starts, not as the limit itself.
The OSHA page adds that NIOSH recommends controlling all worker exposures below a level equivalent to 85 dBA for eight hours, and that NIOSH states significant noise-induced hearing loss occurs at exposure levels equivalent to the OSHA limit.
What an exchange rate means
An exchange rate says how much the allowed time shrinks when the noise gets louder. NIOSH's page states it directly: for each 3 dBA increase in noise level, reduce the exposure duration by half. OSHA uses a 5 dBA exchange rate, so its allowed time halves for each 5 dBA instead.
Turning that into numbers is our own arithmetic from the two stated rules, not a table copied from either agency. With 8 hours at the base level and halving at each exchange step:
- NIOSH time in hours = 8 / 2^((level - 85) / 3)
- OSHA time in hours = 8 / 2^((level - 90) / 5)
| Level | NIOSH recommended time | OSHA limit time |
|---|---|---|
| 85 dBA | 8 hours | not reduced (below 90) |
| 88 dBA | 4 hours | not reduced (below 90) |
| 91 dBA | 2 hours | about 7 hours |
| 94 dBA | 1 hour | about 4.6 hours |
| 97 dBA | 30 minutes | about 3 hours |
| 100 dBA | 15 minutes | 2 hours |
| 103 dBA | about 7.5 minutes | about 1.3 hours |
The gap widens as the noise gets louder. At 100 dBA, NIOSH's recommended time is 15 minutes while the OSHA formula gives 2 hours.
You can try your own level in the noise exposure time calculator, which shows both formulas side by side.
Which one should you follow
If you are an employer in the United States, the OSHA standard is the one you must meet, and the hearing conservation requirement starts at 85 dBA. If you are a person asking what is safer for your own ears, NIOSH's lower number and faster halving are the more cautious choice, and OSHA's own page says that hearing loss occurs at levels equivalent to its limit. Other countries set their own limits, and this page does not cover them. For the 85 dB question in everyday terms, see is 85 decibels loud.
Where a phone fits in
Both rules work on a time weighted average of A-weighted levels, measured with proper instruments over a shift. A phone microphone is not a calibrated instrument, so use it to get a rough feel for how loud a place is, not to prove compliance. Are sound meter apps accurate explains the limits.
Measures noise in decibels and logs it over a session, with a PDF or CSV report.
Get it on Google PlayFree with one small banner ad (no full-screen ads). A one-time Pro unlock removes the ad, gives unlimited session history, and adds PDF and CSV export. There is no subscription.
Sound Meter shows a live decibel estimate with plain quiet, moderate, loud and dangerous zones, and its dangerous line is set at 85 dB. You can start a session and it tracks the minimum, average and maximum level over minutes or hours, with Pro adding PDF and CSV export. It logs minimum, average and maximum levels, which is not the same as a time weighted exposure measurement.