Skip to content

How Loud Should White Noise Be for a Baby

In this guide
  1. What the study measured
  2. What the study did not say
  3. Why the 85 dBA figure appears
  4. How to check a machine yourself

Short answer

The one peer-reviewed measurement study we found, Hugh and colleagues in Pediatrics in 2014, did not set a safe volume for babies. It measured 14 infant sleep machines at maximum volume. All of them were above 50 A-weighted decibels (dBA) at 30 cm, which the authors call the current recommended noise limit for infants in hospital nurseries. Three were above 85 dBA. The authors concluded that these machines can produce levels that may be damaging to infant hearing.

What the study measured

The paper is "Infant sleep machines and hazardous sound pressure levels" by Hugh SC, Wolter NE, Propst EJ, Gordon KA, Cushing SL and Papsin BC, published in Pediatrics 2014, volume 133, issue 4, pages 677 to 681. The points below come from its abstract, which we read through Europe PMC.

  • The researchers measured 14 infant sleep machines played at maximum volume.
  • They measured at 30, 100 and 200 cm from the machine, using correction factors to account for a 6-month-old's ear canal.
  • At 30 cm, every machine was above 50 dBA. The abstract describes 50 dBA as the current recommended noise limit for infants in hospital nurseries.
  • Three machines produced more than 85 dBA. The abstract says that if played at these levels for more than 8 hours, this exceeds current occupational limits for accumulated noise exposure in adults and risks noise-induced hearing loss.
  • The conclusion: sleep machines are capable of producing output levels that may be damaging to infant hearing and auditory development. The authors outline recommendations for safer operation.

What the study did not say

Be careful with what you take from this. These are limits of the source, not extra advice.

  • The measurements were at the machine's maximum volume. The abstract does not say how loud parents usually run them.
  • It measured sound output. It did not test any baby's hearing.
  • The abstract mentions recommendations for safer operation but does not list them. For those, read the full paper (DOI 10.1542/peds.2013-3617).
  • We did not find a figure for a single "right" volume in the abstract, so this page does not give one.

Why the 85 dBA figure appears

The 85 dBA line in the abstract is borrowed from adult workplace guidance. NIOSH, part of the U.S. CDC, recommends an exposure limit of 85 dBA averaged over an eight-hour workday, and recommends halving the exposure time for each 3 dBA increase. That is a guideline for working adults, not a rule written for infants. The study uses it as a comparison point. To see how the time shrinks as the level rises, try the noise exposure time calculator.

How to check a machine yourself

A phone cannot replace a calibrated meter, so treat this as a rough check only.

  1. Run the machine as you normally would, at your usual volume setting.
  2. Hold the phone where the baby's head would be in the cot, with the microphone pointing toward the machine. Keep your hand and body out of the way.
  3. Read the level over a minute or two and compare it with 50 dBA, the nursery figure the study cites.
  4. Note the distance too. The study measured at 30, 100 and 200 cm, because where the machine sits changes the level at the baby's head.
  5. If the reading looks high, ask your paediatrician what to do. Do not rely on a phone number alone.

Phone microphones vary, and many cannot read very quiet or very loud sounds reliably. See are sound meter apps accurate for the limits.

Sound Meter: Noise Log & dB

Measures noise in decibels and logs it over a session, with a PDF or CSV report.

Get it on Google Play

Free with one small banner ad (no full-screen ads). A one-time Pro unlock removes the ad, gives unlimited session history, and adds PDF and CSV export. There is no subscription.

Sound Meter shows the noise level in decibels with plain quiet, moderate, loud and dangerous zones, and can log a session with minimum, average and maximum levels and a graph. It does not make a room safe, measure hearing risk or give medical advice, and phone readings are estimates. For the wider picture on 85 dBA, read is 85 decibels loud.

Sources

  1. Infant sleep machines and hazardous sound pressure levels - Hugh et al., Pediatrics 2014 (abstract via Europe PMC, PMID 24590753)
  2. Noise-Induced Hearing Loss - NIOSH, U.S. CDC

Search the site