Skip to content

Stair Riser and Tread Dimensions Under the IRC

In this guide
  1. The numbers (pages read on 16 November 2026)
  2. Why the tolerance matters
  3. How to work out the number of risers
  4. Common mistakes

Short answer

Under the 2018 International Residential Code, a stair riser can be no higher than 7 3/4 inches (196 mm) and a tread must be at least 10 inches deep. Within one flight, the tallest riser may not exceed the shortest by more than 3/8 inch (9.5 mm), and the same 3/8 inch limit applies to tread depth. To plan a stair, divide the total rise by the maximum riser height and round the number of risers up.

The numbers (pages read on 16 November 2026)

This guide covers the United States model residential code (IRC), edition 2018, for ordinary stairs in houses. States and cities adopt and amend the code, so your local building department decides what applies. It does not cover the UK, Europe or any other country, which have their own rules.

ItemRequirementIRC section
Maximum riser height7 3/4 in (196 mm)R311.7.5.1
Minimum tread depth10 in, measured horizontally from one nosing to the nextR311.7.5.2
UniformityGreatest riser no more than 3/8 in (9.5 mm) above the smallest in a flight; same limit for treadsR311.7.5.1 (risers), R311.7.5.3 as numbered by the summary page (treads)
Nosing3/4 to 1 1/4 in beyond the face of the riser below, may be omitted where risers are opensee the summary page
Headroom6 ft 8 in, measured vertically from the nosingR311.7.2
WidthNot less than 36 in clear of handrailsR311.7.1
Handrail height34 to 38 in, from the tread nosings to the top of the railR311.7.8

The first source is an educational summary of the model code, so confirm any figure with your building department before you build. The South Carolina regulation, which adopts IRC R311.7.5.1, confirms the riser rules in the official text: a maximum of 7 3/4 inches (196 mm), and a maximum of 8 inches (203 mm) for masonry stairs. It also says the riser is measured vertically between the leading edges of adjacent treads, and that risers may be sloped but not more than 30 degrees from vertical.

Open risers

Open risers are allowed, but the gap between treads must not let a 4 inch (102 mm) sphere pass through. The regulation lists an exception: the opening is not limited on stairs with a total rise of 30 inches (762 mm) or less.

Why the tolerance matters

Because the code limits how much risers in one flight may differ, measure the real total rise from finished floor to finished floor, not the rough floor, and share the height equally between all the risers.

How to work out the number of risers

  1. Measure the total rise, from finished floor to finished floor, in one unit.
  2. Divide it by the maximum riser height, 196 mm.
  3. Round up to a whole number. That is the minimum number of risers.
  4. Divide the total rise by that whole number to get the actual riser height. Every riser in the flight should be this height.

Worked example in millimetres

Total rise 2,700 mm.

  • 2,700 / 196 = 13.78, so use 14 risers.
  • 2,700 / 14 = 192.9 mm per riser, under the 196 mm limit.
  • With 13 risers each would be 207.7 mm, which is too tall.

Round up, never down. Each step you add makes every riser a little lower.

Tread depth is separate: it must be at least 10 inches (254 mm) and does not change with the riser count. How many treads you have depends on how the top of the stair meets the upper floor, so draw the section before you cut stringers.

Common mistakes

  • Using the rough floor height instead of the finished floor, so the first or last riser ends up different.
  • Letting one riser or tread vary by more than 3/8 inch (9.5 mm).
  • Measuring tread depth from face to face instead of from nosing to nosing.
  • Treating a summary page as the code. Local rules differ.

Construction Calc

Works out material quantities and measurements for building jobs, metric first with an imperial mode.

Get it on Google Play

Free with a small banner ad and an occasional full-screen ad after you save. Every calculator is free. A one-time Pro unlock removes the ads, allows unlimited saved jobs, and lets you send a job's materials list to WhatsApp, SMS or email. There is no subscription.

Construction Calc has ten calculators, including one for stairs, with metric input where you choose mm, cm or m explicitly. You can save results to a named job as you work through a site.

Sources

  1. IRC 2018 stairway requirements, R311.7 - Jaspector
  2. S.C. Code Regs. 8-1210 (IRC R311.7.5.1 Risers) - Cornell Legal Information Institute

Search the site